Advertisement
Journal of Clinical Oncology  
Search for:
Limit by:
  Browse by Subject or Issue
Home Search or Browse JCO My JCO Subscriptions Customer Service Site Map

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Save to my personal folders
Right arrow Download to citation manager
Right arrowRights & Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schwartz, L. H.
Right arrow Articles by Panicek, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schwartz, L. H.
Right arrow Articles by Panicek, D. M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?
Journal of Clinical Oncology, Vol 18, Issue 10 (May), 2000: 2179-2184
© 2000 American Society for Clinical Oncology


Special Article

Evaluation of Tumor Measurements in Oncology: Use of Film-Based and Electronic Techniques

By Lawrence H. Schwartz, Michelle S. Ginsberg, Douglas DeCorato, Lawrence N. Rothenberg, Steven Einstein, Peter Kijewski, David M. Panicek

From the Departments of Radiology and Medical Physics, Memorial Sloan-Kettering Cancer Center, and Weill Medical College at Cornell University, New York, NY, and Bioimaging Technologies, West Trenton, NJ.

Address reprint requests to Lawrence H. Schwartz, MD, Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Ave, New York, NY 10021-6007; email schwartz{at}msucc.org

PURPOSE: To evaluate the variability in bidimensional computed tomography (CT) measurements obtained of actual tumors and of tumor phantoms by use of three measurement techniques: hand-held calipers on film, electronic calipers on a workstation, and an autocontour technique on a workstation.

MATERIALS AND METHODS: Three radiologists measured 45 actual tumors (in the lung, liver, and lymph nodes) on CT images, using each of the three techniques. Bidimensional measurements were recorded, and their cross-products calculated. The coefficient of variation was calculated to assess interobserver variability. CT images of 48 phantoms were measured by three radiologists with each of the techniques. In addition to the coefficient of variation, the differences between the cross-product measurements of tumor phantoms themselves and the measurements obtained with each of the techniques were calculated.

RESULTS: The differences between the coefficients of variation were statistically significantly different for the autocontour technique, compared with the other techniques, both for actual tumors and for tumor phantoms. There was no statistically significant difference in the coefficient of variation between measurements obtained with hand-held calipers and electronic calipers. The cross-products for tumor phantoms were 12% less than the actual cross-product when calipers on film were used, 11% less using electronic calipers, and 1% greater using the autocontour technique.

CONCLUSION: Tumor size is obtained more accurately and consistently between readers using an automated autocontour technique than between those using hand-held or electronic calipers. This finding has substantial implications for monitoring tumor therapy in an individual patient, as well as for evaluating the effectiveness of new therapies under development.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
JNMHome page
H. A. Jacene, S. Leboulleux, S. Baba, D. Chatzifotiadis, B. Goudarzi, O. Teytelbaum, K. M. Horton, I. Kamel, K. J. Macura, H.-L. Tsai, et al.
Assessment of Interobserver Reproducibility in Quantitative 18F-FDG PET and CT Measurements of Tumor Response to Therapy
J. Nucl. Med., November 1, 2009; 50(11): 1760 - 1769.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Zhao, L. P. James, C. S. Moskowitz, P. Guo, M. S. Ginsberg, R. A. Lefkowitz, Y. Qin, G. J. Riely, M. G. Kris, and L. H. Schwartz
Evaluating Variability in Tumor Measurements from Same-day Repeat CT Scans of Patients with Non-Small Cell Lung Cancer
Radiology, July 1, 2009; 252(1): 263 - 272.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. Girvin and J. P. Ko
Pulmonary Nodules: Detection, Assessment, and CAD
Am. J. Roentgenol., October 1, 2008; 191(4): 1057 - 1069.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. Suzuki, H. Jacobsson, T. Hatschek, M. R. Torkzad, K. Boden, Y. Eriksson-Alm, E. Berg, H. Fujii, A. Kubo, and L. Blomqvist
Radiologic Measurements of Tumor Response to Treatment: Practical Approaches and Limitations
RadioGraphics, March 1, 2008; 28(2): 329 - 344.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Beigelman-Aubry, P. Raffy, W. Yang, R. A. Castellino, and P. A. Grenier
Computer-Aided Detection of Solid Lung Nodules on Follow-Up MDCT Screening: Evaluation of Detection, Tracking, and Reading Time
Am. J. Roentgenol., October 1, 2007; 189(4): 948 - 955.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
J. Desai, S. Shankar, M. C. Heinrich, J. A. Fletcher, C. D. Fletcher, J. Manola, J. A. Morgan, C. L. Corless, S. George, K. Tuncali, et al.
Clonal Evolution of Resistance to Imatinib in Patients with Metastatic Gastrointestinal Stromal Tumors
Clin. Cancer Res., September 15, 2007; 13(18): 5398 - 5405.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Zhao, L. H. Schwartz, C. S. Moskowitz, M. S. Ginsberg, N. A. Rizvi, and M. G. Kris
Lung Cancer: Computerized Quantification of Tumor Response--Initial Results
Radiology, December 1, 2006; 241(3): 892 - 898.
[Abstract] [Full Text] [PDF]


Home page
Neuro Oncol DukeHome page
E. Galanis, J. C. Buckner, M. J. Maurer, R. Sykora, R. Castillo, K. V. Ballman, B. J. Erickson, and for the North central cancer treatment Group
Validation of neuroradiologic response assessment in gliomas: Measurement by RECIST, two-dimensional, computer-assisted tumor area, and computer-assisted tumor volume methods
Neuro-oncol, April 1, 2006; 8(2): 156 - 165.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko, R. Marcus, E. Bomsztyk, J. S. Babb, C. Stefanescu, M. Kaur, D. P. Naidich, and H. Rusinek
Effect of blood vessels on measurement of nodule volume in a chest phantom.
Radiology, April 1, 2006; 239(1): 79 - 85.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. R. Goodman, M. Gulsun, L. Washington, P. G. Nagy, and K. L. Piacsek
Inherent Variability of CT Lung Nodule Measurements In Vivo Using Semiautomated Volumetric Measurements.
Am. J. Roentgenol., April 1, 2006; 186(4): 989 - 994.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Shankar, E. vanSonnenberg, J. Desai, P. J. DiPiro, A. Van Den Abbeele, and G. D. Demetri
Gastrointestinal Stromal Tumor: New Nodule-within-a-Mass Pattern of Recurrence after Partial Response to Imatinib Mesylate
Radiology, June 1, 2005; 235(3): 892 - 898.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. Zhao, L. H. Schwartz, C. S. Moskowitz, L. Wang, M. S. Ginsberg, C. A. Cooper, L. Jiang, and J. P. Kalaigian
Pulmonary Metastases: Effect of CT Section Thickness on Measurement--Initial Experience
Radiology, March 1, 2005; 234(3): 934 - 939.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. T. Boll, R. C. Gilkeson, T. R. Fleiter, K. A. Blackham, J. L. Duerk, and J. S. Lewin
Volumetric Assessment of Pulmonary Nodules with ECG-Gated MDCT
Am. J. Roentgenol., November 1, 2004; 183(5): 1217 - 1223.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
L. H. Schwartz, M. Mazumdar, W. Brown, A. Smith, and D. M. Panicek
Variability in Response Assessment in Solid Tumors: Effect of Number of Lesions Chosen for Measurement
Clin. Cancer Res., October 1, 2003; 9(12): 4318 - 4323.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko, H. Rusinek, E. L. Jacobs, J. S. Babb, M. Betke, G. McGuinness, and D. P. Naidich
Small Pulmonary Nodules: Volume Measurement at Chest CT--Phantom Study
Radiology, September 1, 2003; 228(3): 864 - 870.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
J. J. Erasmus, G. W. Gladish, L. Broemeling, B. S. Sabloff, M. T. Truong, R. S. Herbst, and R. F. Munden
Interobserver and Intraobserver Variability in Measurement of Non-Small-Cell Carcinoma Lung Lesions: Implications for Assessment of Tumor Response
J. Clin. Oncol., July 1, 2003; 21(13): 2574 - 2582.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. R. Prasad, K. S. Jhaveri, S. Saini, P. F. Hahn, E. F. Halpern, and J. E. Sumner
CT Tumor Measurement for Therapeutic Response Assessment: Comparison of Unidimensional, Bidimensional, and Volumetric Techniques—Initial Observations
Radiology, November 1, 2002; 225(2): 416 - 419.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
M. P. Mehta, W. R. Shapiro, M. J. Glantz, R. A. Patchell, M. A. Weitzner, C. A. Meyers, C. J. Schultz, W. H. Roa, M. Leibenhaut, J. Ford, et al.
Lead-In Phase to Randomized Trial of Motexafin Gadolinium and Whole-Brain Radiation for Patients With Brain Metastases: Centralized Assessment of Magnetic Resonance Imaging, Neurocognitive, and Neurologic End Points
J. Clin. Oncol., August 15, 2002; 20(16): 3445 - 3453.
[Abstract] [Full Text] [PDF]



About
JCO
 Editorial
Roster
 Advertising
Information
 Librarians &
Institutions
 Rights &
Permissions
 PDA Services

Copyright © 2000 by the American Society of Clinical Oncology, Online ISSN: 1527-7755. Print ISSN: 0732-183X
Terms and Conditions of Use
  HighWire Press HighWire Press™ assists in the publication of JCO Online