Advertisement
Journal of Clinical Oncology  
Search for:
Limit by:
  Browse by Subject or Issue
Home Search or Browse JCO My JCO Subscriptions Customer Service Site Map

Journal of Clinical Oncology, Vol 24, No 34 (December 1), 2006: pp. 5434-5440
© 2006 American Society of Clinical Oncology.
DOI: 10.1200/JCO.2006.07.9376

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a colleague
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Save to my personal folders
Right arrow Download to citation manager
Right arrowRights & Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lette, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lette, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

A Simple and Innovative Device to Measure Arm Volume at Home for Patients With Lymphedema After Breast Cancer

Jean Lette

From the Department of Nuclear Medicine, Maisonneuve Hospital, Montréal, Québec, Canada

Address reprint requests to Jean Lette, MD, Department of Nuclear Medicine, Maisonneuve Hospital, 5415 Assomption Blvd, Montreal, QC, Canada H1T 2M4; e-mail: jlette{at}lette.com

PURPOSE: We designed an arm volumeter specifically for home use based on the water displacement method. The objective of this study was to determine its accuracy and precision, and compare it with a standard volumeter used in lymphedema clinics worldwide.

PATIENTS AND METHODS: Using a standard model hospital volumeter and our own device, we took three consecutive measurements of 11 specially cast cylinders, which had known volumes ranging from 10mL to 4 L, and measurements of both arms of 15 volunteers.

RESULTS: Measurements with both volumeters were highly accurate (R2 = 0.9999) when compared with the known volumes of the cast cylinders, and were strongly correlated (R2 = 0.9974) when each arm volume was compared between volumeters. Measurements with our volumeter were more precise both with the cylinders (average standard deviation [SD], 3.2 v 8 mL; P = .0553) and with the arms (average SD, 11.1 v 19 mL; P = .0034). Whereas the standard volumeter is expensive, fragile (acrylic), and prone to leaks, our volumeter is inexpensive, virtually indestructible, leak proof, and suitable for home use.

CONCLUSION: Arm volumes can be measured quickly and accurately at home using a simple, inexpensive, and robust device based on water displacement. Readily accessible arm volumetry at home may have widespread influence on the management of lymphedema after breast cancer.

Author's disclosures of potential conflicts of interest and author contributions are found at the end of this article.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?




About
JCO
 Editorial
Roster
 Advertising
Information
 Librarians &
Institutions
 Rights &
Permissions
 PDA Services

Copyright © 2006 by the American Society of Clinical Oncology, Online ISSN: 1527-7755. Print ISSN: 0732-183X
Terms and Conditions of Use
  HighWire Press HighWire Press™ assists in the publication of JCO Online